alle kategorier
EN

Lab handskeboks

Hjem> PRODUKTER > Lab handskeboks

净化真空手套箱1(修改
净化真空手套箱2(修改
净化真空手套箱3(修改)
TENCAN handskerum med rensesystem
TENCAN handskerum med rensesystem
TENCAN handskerum med rensesystem

TENCAN handskerum med rensesystem

Hits: 7

Anvendelse

Applies to making pure environment with removal of water, oxygen and dust.
R&D and production of battery industry (Lithium ion battery, powder battery, solar cell, lithium ion phosphate battery ).

  • video
  • Oversigt
  • Working Princip
  • Funktion/fordele
  • Datablad (EN)
  • Matchbart tilbehør

Applies to making pure environment with removal of water, oxygen and dust.
R&D and production of battery industry (Lithium ion battery, powder battery, solar cell, lithium ion phosphate battery ).
R&D and manufacture of special lamp (HD lamp, metal halide lamp, ceramic metal halide lamp).
Welding (resistance welding, TIG welding, laser welding, plasma welding, brass solder)
R&D and production of OLED
R&D and production of pharmaceuticals
R&D and production of super capacitors
Fine chemical industry
Nuclear industry
R&D and production of new energy materials

The box and purification system are connected together and they both form a well-sealed working environment. When inert gas or nitrogen is filled into the box continuously, the active substances inside the box shall be removed circularly out of the box to keep the inner box in a high cleanness and a high purity inert gas environment (water content≤1 ppm, oxygen content ≤1 ppm) all the time.

Glove box with purification system is a kind of laboratory device which can be filled with a high purity inert gas into the box and active substances can be filtered out of the box circularly. It is also called “vacuum glove box with water and oxygen removal”, and “inert gas purification glove box”. Main functions of this kind of glove box: water content removal, oxygen content removal, other organic gas removal. It is widely used for making high pure environment without water, oxygen and dust content.

TECHNICAL DATA OF TENCAN INERT GAS GLOVE BOX WITH PURIFICATION SYSTEM
Varer data
Water content under the standard condition (Note: The standard condition is one atmospheric pressure, constant temperature of 20 degrees)  ≤1ppm
Oxygen content under the standard condition (The standard condition is one atmospheric pressure, constant temperature of 20 degrees )  ≤1ppm
Max Vacuum Degree which the transition cabinet bears <100pa
Lækagehastighed ≤ 0.05vol%/h
Gas presure range inside the box -3000pa~+3000pa


Specifications of Standard Model of Purification Glove Box
Nej. Model nummer Kassedimensioner Samlede dimensioner Operating Sides Numbers of Gloves Indstillinger
1 GBP800S-2 1200 * 800 * 930mm 1915 * 830 * 1830mm Single 2 Single or double purification columns
2 GBP1000S-2 1200 * 1000 * 930mm 1915 * 1060 * 1830mm Single 2 Single or double purification columns
3 GBP1000D-4 1200 * 1000 * 930mm 1915 * 1060 * 1830mm Dobbelt 4 Single or double purification columns
4 GBP1200S-2 1200 * 1200 * 930mm 1915 * 1260 * 1830mm Single 2 Single or double purification columns
5 GBP1200D-4 1200 * 1200 * 930mm 1915 * 1260 * 1830mm Dobbelt 4 Single or double purification columns







6 GBP800S-3 1500 * 800 * 930mm 2215 * 1060 * 1830mm Single 3 Single or double purification columns
7 GBP1000S-3 1500 * 1000 * 930mm 2215 * 1060 * 1830mm Single 3 Single or double purification columns
8 GBP1000D-6 1500 * 1000 * 930mm 2215 * 1060 * 1830mm Dobbelt 6 Single or double purification columns
9 GBP1200S-3 1500 * 1200 * 930mm 2215 * 1260 * 1830mm Single 3 Single or double purification columns
10 GBP1200D-6 1500 * 1200 * 930mm 2215 * 1260 * 1830mm Dobbelt 6 Single or double purification columns







11 GBP800S-4 1900 * 800 * 930mm 2615 * 1060 * 1830mm Single 4 Single or double purification columns
12 GBP1000S-4 1900 * 1000 * 930mm 2615 * 1060 * 1830mm Single 4 Single or double purification columns
13 GBP1000D-8 1900 * 1000 * 930mm 2615 * 1060 * 1830mm Dobbelt 8 Single or double purification columns
14 GBP1200S-4 1900 * 1200 * 930mm 2615 * 1260 * 1830mm Single 4 Single or double purification columns
15 GBP1200D-8 1900 * 1200 * 930mm 2615 * 1260 * 1830mm Dobbelt 8 Single or double purification columns

Bemærkninger:
Cabinet water and oxygen content under the standard condition:  
Water content ≤1ppm, oxygen content≤1 ppm (Note: Standard condition is that an atmospheric pressure, constant temperature of 20 degree).
Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
Used Gas:
a) Working Gas: N2、Ar、He and etc.
b) Controlling Gas: Compressed air or Inert Gas.
C) Restoring Gas: Mixed gas of working gas and hydrogen.
Restoring gas is as same as working gas if there is only water removal system or oxygen removal system.
Remarks: All Single side boxes of 4 gloves are assembled glove box. Numbers of assembled box can be ordered as per customer’s needs. Quantity of purification columns is also designed to be matched according to customer’s requirements

Glove box with purification system is mainly composed of two parts: a main box body and a transition chamber. We can also design and manufacture customized specifications according to the special requests of the clients.
The main box body has two (two or more) glove operation interfaces in front or back side of the box, which enables one or more people to operate the glove box at the same time, and improves much more efficiency of the glove box utilization. In addition, there are observation windows on the front or back side of the box where people can observe the operation process clearly inside the box. There are air suction and charging nozzles which can be used for air sucking or charging on the valves of the transition cabinet. The main box body is also installed with valve and nozzle, which can be used to maintain air pressure balanced inside the box body if necessary.
The transition cabinet is a transition space between main box body and outside, which is composed of two sealing doors, two valves and a chamber body. Both of the sealing doors can be used effectively to isolate the inner box of the main body from outside of box body. That enables people to send things in or out of the box freely under conditions that the box body is isolated from air atmosphere, avoiding many troubles of repeating evacuation and inflation.